Difference between revisions of "Setup SSVEP BCI example"

From MNE-CPP Wiki
Jump to: navigation, search
(Adjusting the SSVEP-BCI)
(Adjusting the SSVEP-BCI)
Line 12: Line 12:
 
== Adjusting the SSVEP-BCI ==
 
== Adjusting the SSVEP-BCI ==
  
Like already mentioned, in the thesis "[http://opac.lbs-ilmenau.gbv.de/DB=1/SET=2/TTL=1/CMD?ACT=SRCHA&IKT=1016&SRT=YOP&TRM=Development+of+a+BCI+based+on+real-time+neural+source+localization Development of a BCI based on real-time neural source localization]" different scientific approaches are combined in order to realize this BCI. The adjustment of these features can be done by pressing on the configuration icon: [[File:Configuration.png|20px|link=]]
+
Like already mentioned, in the thesis "[http://opac.lbs-ilmenau.gbv.de/DB=1/SET=2/TTL=1/CMD?ACT=SRCHA&IKT=1016&SRT=YOP&TRM=Development+of+a+BCI+based+on+real-time+neural+source+localization Development of a BCI based on real-time neural source localization]" different scientific approaches are combined in order to realize this BCI. The adjustment of these features can be done by pressing on the configuration icon:[[File:Configuration.png|20px|link=]] on the SSVEP-BCI's GUI which is depictured in the previous figure. With this command, the configuration GUI is opened which is shown in the following figure.

Revision as of 14:43, 27 October 2016

Abstract

The SSVEP-BCI plugin beholds a Brain Computer Interface (BCI) using Steady-State-Visual-Evoked-Potentials (SSVEP). It was developed under the Master Thesis "Development of a BCI based on real-time neural source localization", in which the so called Bremen-BCI was used as a role model in order to setup classification pipeline and visualization. This tutorial describes both the setup of the processing pipeline and usage of the SSVEP-BCI plugin.

Editing the Processing Pipeline

In the following figure an edited setup of the SSVEP-BCI processing pipeline is shown in the MNE-Scan GUI environment. For this example the NoiseReduction plugin was interposed as a preprocessing step in order to increase the Signal-to-Noise ratio. However, the SSVEP-BCI plugin can also be processed with "raw" (unfiltered) data by connecting it directly with the acquisition plugin.

SSVEP BCI processing pipeline in the MNE-Scan environment


Adjusting the SSVEP-BCI

Like already mentioned, in the thesis "Development of a BCI based on real-time neural source localization" different scientific approaches are combined in order to realize this BCI. The adjustment of these features can be done by pressing on the configuration icon:Configuration.png on the SSVEP-BCI's GUI which is depictured in the previous figure. With this command, the configuration GUI is opened which is shown in the following figure.